f y in p b t

+8615280858852

sales@avenotester.com

Englishen españoles portuguêspt

Search

Home /

Search

  • Use Of The 100CM² Sample Cutter

    2019-05-22

    Place the sample on the cutting board making sure that it is flat and smooth, do not stretch 100CM² Sample Cutter. Place the cutter on the sample and release the safety catch, this is done by withdrawing the head of the catch, turning it through 90 degrees and locating the pin in the two recesses, this allows the blades to become operational. Whilst holding the cutter with one hand, apply pressure...

  • AC12 Precision Drying Oven use precautions

    2019-07-11

    1. The shell of the Drying Oven shall be well grounded to guarantee the safe use. 2. The Drying Oven shall be placed inside one well-ventilated room, surrounding which no inflammable and explosive articles are available. 3. The Drying Oven has no explosion-proof device, so never place inflammable and explosive articles inside for drying. 4. The articles in the cabinet shall not be too crowded. Cer...

  • Operation Of Button Impact Resistance Tester

    2020-07-25

    Sample Prepare Laboratory Sample - As a laboratory sample, randomly select a quantity of buttons, approximately 100 to 200, from a carton and from contained boxes, that adequately represents the material, from which test specimens may be selected. Test Specimens - Randomly select 15 buttons from the laboratory sample for testing. If test specimens are submitted for preproduction approval, testing ...

  • How to use the Precision Drying Oven

    2021-02-26

    1. Put the articles to be dried into the Laboratory Drying Oven, close well the door and turn the air door adjusting knob to “ ” position. 2. Move the power switch to “ON”. The power indicator light lights up and figures appear on the temperature control instrument. 3. Select the required set temperature, the numeric temperature displayed at the moment is the temperature in the cabinet and the hea...

  • ROLLER ROTATION DIRECTION

    2021-07-05

    We recommend that you do not perform the following operations on the ROLLER ROTATION DIRECTION to ensure safety. More about Electronic Laboratory Padder please click: https://www.avenotester.com/electronic-laboratory-padder-ac24_p239.html Contact Us Now! Sales Dept Tel: +86 15280858852 Email: sales@avenotester.com Skype: sales@avenotester.com Web: www.avenotester.com

  • Operating specifications Of Manual Fabric Stiffness Tester

    2021-11-22

    1. Prepare the test piece of Manual Fabric Stiffness Tester: 1) Use scissors to cut out the size of 25mm×200mm from the sample to be tested, with the long side of the sample facing the warp direction, the weft direction, and three samples each without damage and defects. If possible, samples in all directions should not contain the same number of warp (weft) yarns. 2) Specimen processing: All spec...

1 2