  • Press the test to enter the work interface, the screen will show following:




(1) When the Martindale Abrasion Tester is not in working state, Click “Times” button to set test times. The setting range is 0~999999 times.

(2) When the Martindale Abrasion Tester is not in working state, Click “Speed” button to set test speed. The speed setting range is 20~70r/min.

(3) When the Martindale Abrasion Tester is not in working state, Click “Method” button to set counting mode, increase counting and down counting.

(4) Click the test position button to choose weather the position is count or not.

                                          


      Test position is selected           Test position was not selected

(5) To start the test button, when the test preparation is completed, click this button to run the Abrasion and Pilling Tester and switch to the stop button.

                                         


                      Stop                                      start up

(6) Reset button, to reset the number of times of all test position.



(7) Test progress bar, you can watch the progress of the experiment, showing the fastest progress of all selected test positions, and the Abrasion and Pilling Tester will stop when there is a test position finished.